Solar panels typically lose around 0.5% of their rated output each year. The review done by NREL presented nearly 2,000 photovoltaic degradation measurements and found a median annual degradation rate of 0.5%. However, the actual rate varies with module technology used in solar panels, climate change, and operating conditions. NREL study, covering more than 1,700 solar installations, reported a median system performance loss of 0.75% per year.
While these figures may appear small, their impact accumulates over a solar plant’s operating life. Gradually declining generation affects long-term energy forecasts, project economics, and the planning of electrical panels used in solar installations, along with the monitoring systems needed to track performance.
This makes solar panel degradation more than a module performance issue. It also raises important questions about electrical panel sizing, future system expansion, and how monitoring systems distinguish normal aging from unexpected performance losses.
This article explains how much solar panel output typically declines each year, what causes the reduction, and what buyers and project developers should consider when planning for long-term system performance.
What is solar panel degradation?
Degradation is the gradual fall in a panel’s power output as it ages. It is not a fault. Every crystalline silicon panel degrades, and manufacturers build the expectation into the product itself through the warranty.
Two factors drive solar panel degradation, and each affects your panels differently.
Light-induced degradation (LID) happens once, early, and then stops. Within the first weeks of sun exposure, a chemical reaction inside the cell causes a small, one-time drop in output, typically 1 to 2 percent. That is why a fresh panel’s output in month two is lower than its rating, even though nothing has gone wrong.

Long-term degradation is the slow, ongoing process that follows for the rest of the panel’s life. UV exposure, heat cycling, moisture at the cell edges, and gradual discolouration of the encapsulant each play a part. Together, they reduce a significant percentage of output each year over the panel’s lifespan.

Not every drop in solar generation is permanent degradation. Most common issues like dust, bird droppings, and other surface deposits can block sunlight from reaching the cells, reducing output until the modules are cleaned. This is known as soiling loss and should be distinguished from the panel’s gradual ageing.
Physical damage can also affect long-term performance. Hail impact, repeated wind loading, and rough handling during transportation or installation can create microcracks in solar cells. These cracks may interrupt electrical pathways and contribute to additional power loss over time.
How much output you lose, and when
Annual solar panel degradation is commonly reported in the range of 0.5% to 0.8%, although the actual rate varies with module technology, climate, and operating conditions.
The National Renewable Energy Laboratory’s PV Fleet Performance Data Initiative studied data from nearly 19,000 inverters across commercial, industrial, and utility-scale US systems. It found a median performance loss of around 0.75 percent a year across the fleet studied.
A field study led by Sandia National Laboratories, examining 834 PV modules across 13 module types, reported mean and median degradation rates of 0.6% per year. These findings broadly align with historical research, which has reported degradation rates between 0.5% and 0.9% per year, depending on the study.
Two things change that number for a specific site.
Climate: According to an NCPRE, IIT Bombay analysis, based on more than 2,300 degradation samples from Indian solar installations, found a median annual degradation rate of 1.03% in hot climates, compared with 0.30% in non-hot climates. These findings highlight how local climate conditions can influence long-term solar panel performance.
The first year is different from every year after it: Manufacturer warranties consistently separate year one from the rest of the panel’s life. A representative structure, drawn from several major manufacturers’ published warranty documents, guarantees output at roughly 97 to 98 percent of nameplate by the end of year one. That first-year loss, 2 to 3 percent, is larger than any single year that follows. From year two onward, the decline flattens to a straight line, commonly 0.4 to 0.55 percent a year, continuing out to 84 to 87 percent of nameplate by year 25.
That shape, a steeper first-year drop followed by a long, gentle slope, is what the diagram below shows.

What does this mean for long-term output?
Consider a panel that loses 2% of its rated output in the first year, followed by an annual degradation rate of 0.5%. Its remaining output would be approximately 93% after 15 years and 86% after 25 years, measured against its original nameplate rating. These figures are illustrative, as actual output retention depends on the panel’s degradation warranty and operating conditions.
Why “it varies” is not good enough for a buying decision
Degradation changes a plant’s output forecast, and a forecast error compounds over a 25-year asset life. It also changes two key decisions you make on day one, which are costly to fix down the road.
Electrical panel sizing: The LT panels on a plant, PCC (Power Control Center) , Motor Control Center (MCC), and Automatic Power Factor Correction panels (APFC) boards, among them, get specified against the load the system presents when it is new. A panel sized with no spare capacity fits perfectly on day one and still fits on day 9,000, because the load it sees only ever falls from there. The real risk runs the other way: a panel sized too tightly to allow for a planned expansion, or for a battery storage retrofit, forces a swap years into the asset’s life instead of a straightforward addition.
GP Eco Solutions ‘buying guide for electric panels and inverters and its breakdown of the difference between HT and LT panels are useful starting points before finalising a panel order.
Monitoring: From the meter alone, a 0.7 percent annual decline and a loose connection that is quietly costing the same amount look identical. Both show up as “output a bit lower than expected.” The only way to tell them apart is a monitoring system that logs generation data over time and can show a trend line, not just a snapshot.

What to ask about before you sign off a system
A few checks catch most of the cost that degradation adds later.
- Ask for the linear power warranty table, not just the headline warranty years: A 25-year warranty is not one number. It is a year-by-year schedule, and the shape of that schedule, especially the first-year step, tells you more than the endpoint does.
- Size electrical panels and switchgear with room for the system’s life, not just its first day: If expansion or battery storage is plausible within the plant’s life, say so at the specification stage.
GP Eco Solutions’ guide on working out the right solar capacity for a business covers how sizing decisions get made before panels are even ordered.
- Confirm what the monitoring system actually logs: A system that reports live output but keeps no historical record cannot show a trend.
GP Eco Solutions’ explainer on solar SCADA monitoring walks through what SCADA covers, including real-time tracking, alarm and fault detection, and historical trend analysis, which is the specific feature that turns a single low-output day into evidence of a real decline instead of a one-off.
- Check your supplier’s track record before the warranty becomes the only thing standing behind the panel: A manufacturer’s 25-year promise is only worth as much as the company is likely to still exist to honour it.
How to choose a solar supply partner sets out what to verify before buying.
The forward look
Degradation research is still active. The newest cell technologies, like TOPCon and heterojunction modules among them, show different early-life behaviour from the older PERC panels most Indian installations still use.
The degradation profile also varies by cell technology. N-type TOPCon and heterojunction (HJT) modules are often marketed with lower annual degradation rates than conventional P-type Mono PERC modules. However, the exact rate depends on the manufacturer, module design, and warranty conditions.
For a meaningful comparison, check each manufacturer’s first-year degradation allowance, annual degradation rate thereafter, and guaranteed output at year 25 or 30. A lower advertised annual rate alone does not establish better long-term performance.
Some newer cell types show a small performance gain in their first year or so before degradation sets in, instead of the usual early dip. A handful of early-generation examples of the newest technologies have also shown faster-than-average decline in small field studies. The data set for these newer technologies is still young. Treat any manufacturer’s degradation claim for a cell type with fewer than five years of field history as a number to verify against the actual linear warranty schedule, not as settled fact.
Getting the panel sizing and monitoring right from the start
Solar panel degradation is an expected part of a system’s operating life. Linear power warranties account for this gradual decline, but proper planning is still important. The risk is specifying the electrical panels and monitoring only the system’s first day, then discovering years later that there is no room to expand and no record showing whether the shortfall is normal ageing or a developing fault.
This is where the right equipment and monitoring setup matter.GP Eco Solutions supplies LT and HT electrical panels, solar inverters, storage solutions and SCADA monitoring systems. Its SCADA solutions support real-time generation tracking, alarm and fault detection, and historical trend analysis, helping plant operators identify performance changes and investigate unexpected output losses.
Whether you are planning a new solar installation or reviewing the electrical infrastructure for an existing plant, GP Eco Solutions can help you identify suitable equipment for your project requirements.
Connect with the GP Eco Solutions team to discuss your panel requirements and solar monitoring needs.
Frequently asked questions
Is 0.5 percent degradation a year good or bad?
It sits at the better end of the typical range. Most crystalline silicon panels fall somewhere between 0.5 and 0.8 percent a year, so 0.5 percent is a reasonable, slightly better than average result, not an exceptional one.
Does a panel stop working once it degrades past its warranty line?
No, the panel keeps generating power. The warranty line is the point below which the manufacturer owes a remedy, usually repair, replacement, or a payout, not the point at which the panel fails outright. Most panels keep producing well past 25 years, just below their original rating.
Can bad installation make degradation worse?
Yes, poor racking that traps heat, inadequate ventilation behind the panels, and connections that were not torqued to specification can all accelerate the long-term decline beyond what the panel’s own warranty assumes. This is a workmanship issue, separate from the panel’s own degradation rate.
Do electrical panels and switchgear degrade the same way solar panels do?
No, LT and HT electrical panels do not have a power output to decline. They age through wear on breakers, connections, and insulation, which is why they are specified and maintained differently from the PV modules feeding them.
How do I know if my system is degrading faster than it should?
Compare year-over-year generation data, adjusted for irradiance, against the manufacturer’s linear warranty schedule. A monitoring system with historical trend data makes this a five-minute check. Without one, it requires manual log-keeping that most owners never do consistently.